2-Valve Manifold (2VMNT-8N-SS)
 catalog
|
Kor-Lok 2-Valve Manifolds offer safety and
reliability in a general purpose design. The
simple 2-Valve configuration allows for easy
block, bleed and calibration of a static
pressure transmitter or gauge. Valves are
available with either metal seats or
replaceable soft seat inserts. Connections are
1/2" female NPT on all three ports.
Specifications * Connection: 1/2" Female NPT to 1/2" Female
NPT * One-piece, high strength body construction
for safety -- no welding used. * Stems feature a non-rotating tip with an
easily replaceable soft insert * Bonnet lock pin prevents accidental valve disassembly * 316 stainless steel construction for superior
corrosion resistance * Bonnet-to-body seals are metal-to-metal-no
O-Rings used * Mounting holes provided for self-supporting applications * 100% pressure tested for shut-off and at all
seals * Manifolds feature a 4:1 safety factor |
MATERIALS OF CONSTRUCTION
|
No.
|
Component
|
Material Specification
|
|
1
|
Handle
|
Stainless Steel
|
|
2
|
Handle Pin
|
17-4PH Stainless
|
|
3
|
Set Screw
|
|
4
|
Packing Nut
|
Stainless Steel
|
|
5
|
Upper Gland
|
|
6
|
Packing
|
TFE/D 1710 or Grafoil
|
|
7
|
Lower Gland
|
316SS
|
|
8
|
Bonnet
|
|
9a
|
Stem (NeedleTip)
|
|
9b
|
Stem (Vee Tip)
|
|
10
|
Soft Seat (Vee Tip)
|
Delrin
|
|
11
|
Cap Screw
|
Stainless Steel
|
|
12
|
Lock Plate
|
|
13
|
Manifold Body
|
316SS
|
|

|
|
Safe Manifold Selection
When selecting a manifold, the total system design
must be considered to ensure safe, trouble-tree
performance. Valve function, materials
compatibility, adequate ratings, proper
installation, operation, and maintenance are the
responsibility of the system designer and user.
|
|
|
TABLE OF DIMENSIONS
|
SCHEMATIC DIAGRAM
Manifold Selection Information
The pressure-temperature ratings are taken for ANSI B16.34
for standard class valves and based on Class 2500.
Rating for needle tip designs are based on specific seat
materials.
★ ORIFICE : 3.2mm (0.125")
★ WEIGHT : Approximate 0.9KG (2 lbs)
TESTING
Standard production test - Each valve on every manifold is
factory tested with nitrogen at 1000psig(68bar) for
leakage at the seat, packing and shell. Each test is
performed to a maximum allowable leak rate of 0.1 scc/min.
|
|
A
|
B
|
C
|
D
|
E
|
F
|
G
|
H
|
I
|
J
|
K
|
L (Open)
|
M
|
|
47.6
|
50.8
|
96.8
|
7.9
|
9.5
|
22.2
|
15.9
|
33.3
|
63.5
|
31.7
|
15.9
|
78.5
|
32
|
MANIFOLD SELECTION TECHNICAL DATA
|
Stem
Design
|
Part No.
|
Seat
|
Pressure
Rating
|
Pressure Rating
Max. Temperature
|
Packing
|
|
Needle Tip
|
2VMNT-8N-SS
|
316SS
|
413KG/CM²from
-54°C to 38°C
(6000PSIG from
-65°F to 100°F)
|
284KG/CM²@232°C
(4130 PSIG @450°F)
|
TFE
|
|
2VMNG-8N-SS
|
233KG/CM²@454°C
(3380 PSIG @850°F)
|
Grafoil
|
|
Vee Tip
|
2VMVD-8N-SS
|
Delrin
|
172KG/CM²@121°C
(2500 PSIG @250°F)
|
TFE
|
|

Kor-Lok USA, LLC
15060 West Drive, Suite 100
Houston, Texas 77053